What is the process for FDA registration and certification?
Category:行業(yè)資訊 Date:2024-08-22 16:48:54 Author: Source:
This process ensures that medical devices meet safety and effectiveness standards before they can be marketed in the U.S.

The process for FDA registration and certification of medical devices involves several steps to ensure compliance with regulatory requirements. Here is an overview of the process:1(1).jpg

  1. Determine Device Classification:

    • Class I: Low risk; often exempt from premarket notification.
    • Class II: Moderate risk; requires premarket notification (510(k)).
    • Class III: High risk; requires premarket approval (PMA).
  2. Establish a Regulatory Pathway:

    • 510(k) Premarket Notification: For most Class II devices, demonstrating substantial equivalence to an existing device.
    • Premarket Approval (PMA): For Class III devices, requiring detailed clinical data and a more rigorous review process.
    • De Novo Classification: For novel devices without a predicate, establishing a new classification.
  3. Prepare and Submit Documentation:

    • Device Listing: Register the device and provide details about the manufacturer and device.
    • 510(k) Submission: Include data showing substantial equivalence to a predicate device.
    • PMA Submission: Provide clinical trial data, device description, manufacturing information, and labeling.
  4. Quality System Regulations (QSR):

    • Implement and maintain a Quality Management System (QMS) in compliance with FDA regulations, including design controls, production processes, and documentation.
  5. FDA Review:

    • 510(k) Review: The FDA reviews the substantial equivalence claim, which usually takes about 90 days.
    • PMA Review: A more extensive review process, often taking several months to over a year, including a detailed examination of clinical data and manufacturing processes.
  6. FDA Inspection:

    • The FDA may inspect the manufacturing facility to ensure compliance with QSR and other regulations.
  7. Post-market Requirements:

    • Adverse Event Reporting: Report any adverse events or device-related issues to the FDA.
    • Ongoing Compliance: Maintain compliance with FDA regulations, including labeling, manufacturing practices, and periodic inspections.

This process ensures that medical devices meet safety and effectiveness standards before they can be marketed in the U.S.

Contact Us:

Whatsapp or Wechat:+86 15816864648;email address:hito.lin@grzan.cn